Entry  Tue Jun 5 20:42:59 2012, Suresh, Summary, IOO, Tip-Tilt Cabling 40m_Tip-tilt_cabling.png
    Reply  Tue Jun 5 22:39:06 2012, Jenne, Summary, IOO, Tip-Tilt Cabling 
       Reply  Wed Jun 6 01:23:32 2012, Suresh, Summary, IOO, Tip-Tilt Cabling 
Message ID: 6756     Entry time: Tue Jun 5 20:42:59 2012     Reply to this: 6759
Author: Suresh 
Type: Summary 
Category: IOO 
Subject: Tip-Tilt Cabling 

I have made a preliminary sketch of the cabling involved in connecting the Tip-tilt coil drivers.   This is a preliminary document. 

40m_Tip-tilt_cabling.png

 

 

  Required parts Quantity Solution
1) DAC Card inserted into C1IOO machine 1 buy or borrow from Cymacs
2) SCSI cable from DAC to D080303 box 1 buy or find at the 40m
3) D080303 box (SCSI to IDC breakout box) 1 Jay may have had spare, if not we have to make one
4) 40 pin IDC cables from D080303 to AntiImaging filter 2 Jay may have kept some stock if not make them
5) 10 pin IDC cables from Anti Imaging filters to Whitening filters 2 make
6) sma to lemo cables from Whitening to coil drivers 4x4=16 buy
7) 15pin IDC to 25pin DSub cables from drivers to feedthroughs on the chambers 4  (length?) make
8) 25pin DSub feedthrough on OMC chamber 1 check in 40m stock else buy
9) 25pin DSub  Kapton strip cable from OMC wall to table top 1 check if any spare are available in aLIGO stock
10) 25pin DSub Kapton strip cable from post to tip-tilt 4 aLIGO team said they have a few to spare if not buy
10) Quadrapus cables on the tip-tilts 4 Jamie is negotiating with aLIGO cable team

 

ELOG V3.1.3-