Fri Jun 1 14:56:08 2012, Jamie, Update, SUS, Oplevs all different, messed up
|
Fri Jun 1 18:07:32 2012, steve, Update, SUS, Oplevs servo values
|
Fri Jun 1 19:48:54 2012, rana, Update, SUS, Oplevs all different, messed up
|
Wed Jul 11 16:19:08 2012, yuta, Update, SUS, oplev servo phiology
|
|
Message ID: 6745
Entry time: Fri Jun 1 19:48:54 2012
In reply to: 6743
|
Author: |
rana |
Type: |
Update |
Category: |
SUS |
Subject: |
Oplevs all different, messed up |
|
|
Its a good question, but the answer is yes. At some level all of the OL servos should be different to handle the different mechanical resonances of the suspension as well as the optical table's acoustic noise and the different noise requirements for the difference optical cavities.
However, it would be better to have the same basic structure and then one or two customization filters. |