Quote: |
..........
- Tip Tilts
- Prepare electronics for TTs (coil drivers) - JAMIE
- In-air TT testing to confirm we can control / move TTs before we vent - SURESH
- Connect TTs to digital system and controls, lay cables if needed - JAMIE with SURESH
- .....
|
[Koji, Suresh]
We tried to locate the sixteen analog output channels we need to control the four tip-tilts (four coils on each). We have only 8 available channels on the C1SUS machine.
So we will have to plug-in a new DAC output card on one of the machines and it would be logical to do that on the C1IOO machine as the active tip-tilts are conceptually part of the IOO sub-system. We have to procure this card if we do not already have it. We have to make an interface between this card output and a front panel on the 1X2 rack. We may have to move some of the sub-racks on the 1X2 rack to accommodate this front panel.
We checked out the availability of cards (De-whitening, Anti-imaging, SOS coil drivers) yesterday. In summary: we have all the cards we need (and some spares too). As the De-whitening and Anti-imaging cards each have 8 channels, we need only two of each to address the sixteen channels. And we need four of the SOS coil drivers, one for each tip-tilt. There are 9 slots available on the C1IOO satellite expansion chassis (1X1 rack), where these eight cards could be accommodated.
There are two 25 pin feed-thoughs, where the PZT drive signals currently enter the BS chamber. We will have to route the SOS coil driver outputs to these two feed-throughs.
Inside the BS chamber, there are cables which carry the PZT signals from the chamber wall to the the table top, where they are anchored to a post (L- bracket). We need a 25-pin-to-25-pin cable (~2m length) to go from the post to the tip-tilt (one for each tip-tilt). And then, of course, we need quadrapus cables (requested from Rich) which fit inside each tip-tilt to go to the BOSEMs.
I am summarising it all here to give an overview of the work involved.
|