Message ID: 6619     Entry time: Mon May 7 22:39:37 2012
Author: Den 
Type: Update 
Category: CDS 
Subject: c1sus 

[Jenne, Den]

We decided to reboot C1SUS machine in hope that this will fix the problem with seismic channels. After reboot the machine could not connect to framebuilder. We restarted mx_stream but this did not relp. Then we manually executed

/opt/rtcds/caltech/c1/target/fb/mx_stream -s c1x02 c1sus c1mcs c1rfm c1pem -d fb:0 -l /opt/rtcds/caltech/c1/target/fb/mx_stream_logs/c1sus.log

but c1sus still could not connect to fb. This script returned the following error:

controls@c1sus ~ 128$ cat /opt/rtcds/caltech/c1/target/fb/mx_stream_logs/c1sus.log


c1x02
c1sus
c1mcs
c1rfm
c1pem
mmapped address is 0x7fb5ef8cc000
mapped at 0x7fb5ef8cc000
mmapped address is 0x7fb5eb8cc000
mapped at 0x7fb5eb8cc000
mmapped address is 0x7fb5e78cc000
mapped at 0x7fb5e78cc000
mmapped address is 0x7fb5e38cc000
mapped at 0x7fb5e38cc000
mmapped address is 0x7fb5df8cc000
mapped at 0x7fb5df8cc000
send len = 263596
OMX: Failed to find peer index of board 00:00:00:00:00:00 (Peer Not Found in the Table)
mx_connect failed

Looks like CDS error. We are leaving the WATCHDOGS OFF for the night.