Message ID: 6614     Entry time: Mon May 7 19:39:52 2012     In reply to: 6613     Reply to this: 6615
Author: Koji 
Type: Update 
Category: IOO 
Subject: WFS noise in MC 

OK. Then we should make this number bigger such that the coherence is still completely maintained.
Is this set in the auto locker? Or manually set?

Quote:

  This effect is due to C1:IOO-WFS1_PIT_LIMIT=2000. When I turned if off, coherence between C1:IOO-WFS_PIT input and output signals restored

 