- General
- More LCD screens! Wider screens!
- Allegra - only can handle single head right now, but should prepare for the eventual upgrade of that videocard/whole computer and get 2 monitors.
- Every workstation should have 2 24" monitors. We currently have 2 good ones (one on Rossa, one on Pianosa), so we need 6.
- Remove Control room shelf currently holding OSA 'scopes
- Adjust both TV shelves so that they're at the same height, ~6" higher than the current left shelf.
This gives space for stacking the 24" monitors for each computer.
- Audio system for the signals!!!! Even a crappy one!
/cvs/cds/ligo/centos5.5/cds/project/gds-2.14.2/Monitors/rockIFO
/cvs/cds/gds/gds/Monitors/rockIFO
(really /cvs/cds, not /opt)
- IOO
- PZT or Picomotor mounts for PSL/ALS beams
- ALS on the both arm simultaneously / common/diff ALS scripts
- SUS
PRM OPLEV servos are sometimes not stable. (fixed, JCD/DM/KA, 5/2/2012)
- ETMX oplev - replace 1064nm lens with 632nm lens (KBC037, -100)
- IFO
- It seems that there is an occasional common-mode power transient in the arm transmissions.
-> Track down the cause and fix.
- Fix arm ASS even on CentOS
- Drift of the green incident axis -> Assess the amount of the drift / replace the mount
- Calibration of POP22 / AS110
- PMC/IMC/ARM characterization (loss, finesse, reflectivity, etc)
- CDS
- Capture OSA signals in CDS (the 'scope TDS1001B has a USB port in the back for connecting to the computer)
- Transmon (arms) for high and low power
- POX11 whitening is not toggling the analog whitening???
- CentOS machines cannot open simulink models properly (get "Bad Link"s everywhere, so you can't do anything useful).
- Dataviewer and DTT can't connect to framebuilder from CentIOS machines
- Electronics
- Actuator noise level characterization (coil driver response in V/m & coil driver noise level V/rtHz)
- Beat box
- I/Q DFD
- Improvement of POP22/110/AS110 RF circuits.
- MEDM
OL alert in the watch dog screen (this is awesome!) should have small text saying "OL" (done, JCD, 5May2012)
- Complete 40m overview screen - everything should be clickable with pseudo 3D icons
- BETTER SUSPENSION SCREEN!!!
- Script to generate a MEDM tree
- Resurrect MEDM snapshots
The LSC screen has some "white" boxes -> investigate and fix them (done, KA, 5/2/2012)
Make the LSC control screen (compact) in the vertical arrangement (done, KA, 5/2/2012)
The signals of the watch dog screen should go red if any of the WDs are not enabled.
=>Copy the logic of the signals in LSC screen. (done, KA, 5/2/2012)
Remove c1gfd from the cds status screen (done, KA, 5/2/2012)
Add "BURT" status indicators on the cds status screen (done, KA, 5/2/2012)
- SCRIPT
- Locking scripts with integrator triggers / disabling when unlocked
- Daily diagnosis of the MC spot positions (there must be something already...)
- Daily/occasional adjustment of the incident axis on the MC
Suspension "misalign/restore" script is too wild => make a new script (Done, JCD, 7May2012)
- IFO_CONFIGURE scripts still do a burt restore, so step the optics. Need to remove optic alignment from config .snap files, use reg restore script instead.
- OPLEV/OSEM trending script before the IFO work for diagnosis.
- Auto-locker for PMC/Arm/etc
- Video
- If each video screen has a caption, that would be great
- GUI interface of "videoswitch" Mike!
- Mouse Jiggler for Zita (called Swinput?)
- Ubuntu
burttoday is not aliased in ubuntu. burttoday: aliased to cd /opt/rtcds/caltech/c1/burt/autoburt/today/
- ASS doesn't run on Ubuntu!
ezcawrite: error while loading shared libraries: libca.so: cannot open shared object file: No such file or directory
ezcaswitch: error while loading shared libraries: libca.so: cannot open shared object file: No such file or directory
|