40m QIL Cryo_Lab CTN SUS_Lab TCS_Lab OMC_Lab CRIME_Lab FEA ENG_Labs OptContFac Mariner WBEEShop
  40m Log  Not logged in ELOG logo
Entry  Mon Mar 26 23:47:54 2012, Suresh, Update, IOO, Beam Profile measurement: IPPOS beam BeamProfile_IPPOS.pngBeamProfile_IPPOS.pdfBeamProfileData_IPPOS.xlsx
    Reply  Tue Mar 27 02:05:40 2012, Suresh, Update, IOO, Beam Profile measurement: IPPOS beam BeamProfile_IPPOS.pngBeamProfile_IPPOS.png
       Reply  Tue Mar 27 11:54:18 2012, Jenne, Update, IOO, Beam Profile measurement: IPPOS beam IPPOS_distances.pdf
          Reply  Tue Mar 27 18:03:46 2012, Jenne, Update, IOO, Beam Profile measurement: IPPOS beam BeamProp_usingMeas2012MMTnumbersLowRes.png
             Reply  Tue Mar 27 21:20:32 2012, Jenne, Update, IOO, Beam Profile measurement: IPPOS beam BeamProp_usingMeas2012MMTnumbersLowRes.png
                Reply  Tue Mar 27 23:37:35 2012, Suresh, Update, IOO, Beam Profile measurement: IPPOS beam Beam-Profile_IPPOS_wError.png
                Reply  Wed Mar 28 01:17:29 2012, Jenne, Update, IOO, Beam Profile measurement: IPPOS beam BetterDistances_IPPOSLowRes.pngBetterDistances_MainIFO_PRMnormalLowRes.pngBetterDistances_MainIFO_PRMflippedLowRes.png
                   Reply  Wed Mar 28 18:26:47 2012, Jenne, Update, IOO, Beam Profile measurement: IPPOS beam OptimizedMMT_halfMeterChange_IPPOSviewLowRes.pngOptimizedMMT_halfMeterChange_IFOviewLowRes.pngOptimizedMMT_pt2cMeterChange_IPPOSviewLowRes.pngOptimizedMMT_pt2cMeterChange_IFOviewLowRes.png
                      Reply  Wed Mar 28 20:54:02 2012, Jenne, Update, IOO, Beam Profile measurement: IPPOS beam MMT_moved_by_1pt3meters_MMT1th_25_MMT2th_12_LowRes.pngMMT_moved_by_1pt3meters_MMT1th_25_MMT2th_12_LowRes.png
                         Reply  Mon Apr 2 18:58:32 2012, Jenne, Update, IOO, Beam Profile measurement: IPPOS beam NonOptimized_propagatedWaistPlotted_LowRes.png
                         Reply  Mon Apr 2 23:06:38 2012, Suresh, Update, IOO, Beam Profile measurement: IPPOS beam: Mystery deepens 40mOpticsLocations.pdfBeam-Profile_IPPOS_wError.pdfBeam-Profile_PRM_1_wError.pdf
       Reply  Tue Mar 27 17:19:02 2012, Koji, Update, IOO, Beam Profile measurement: IPPOS beam 
    Reply  Tue Mar 27 02:18:31 2012, keiko, Update, IOO, Beam Profile measurement: IPPOS beam text9149.pngfirst_cap.pngsecond_cap.pngtext9149.png
       Reply  Tue Mar 27 16:06:59 2012, keiko, Update, IOO, Beam Profile measurement: IPPOS beam 
Message ID: 6451     Entry time: Tue Mar 27 11:54:18 2012     In reply to: 6448     Reply to this: 6456
Author: Jenne 
Type: Update 
Category: IOO 
Subject: Beam Profile measurement: IPPOS beam 

I'd like to know what we expect for these numbers.  I've added to Kiwamu's drawing some more distances, so I can calculate the expected beam size at the IPPOS port.

IPPOS_distances.pdf

 

Quote:

Quote:
 

  Vertical

Vertical 

06/18/2010

Horizontal

Horizontal

06/18/2010

waist (radius) (mm) 2.77 2.81 2.47 2.91
Rayleigh length (m) (computed) 22.62   18.14  
Waist location w.r.t. to MM2 * 3.37 5.36 4.15 1.96

 