It appears that the old PSL fast channels never made it into the new DAQ system. We need to figure out what to do with them.
A D990155 DAQ Interface card in far right of the 1X1 PSL EuroCard ("VME") crate is supposed output various PMC/FSS/ISS fast channels, which would then connect to the 1U "lemo breakout" ADC interface chassis. Some connections are made from the DAQ interface card to the lemo breakout, but they are not used in any RTS model, so they're not being recorded anywhere.
An old elog entry from Rana listing the various PSL DAQ channels should be used as reference, to figure out which channels are coming out, and which we should be recording.
The new ALS channels will need some of these DAQ channels, so we need to figure out which ones we're going to use, and clear out the rest.
|