40m QIL Cryo_Lab CTN SUS_Lab TCS_Lab OMC_Lab CRIME_Lab FEA ENG_Labs OptContFac Mariner WBEEShop
  40m Log  Not logged in ELOG logo
Entry  Fri Feb 3 17:31:09 2012, steve, Update, General, green welding glass 02031202.JPG
    Reply  Tue Feb 14 17:09:05 2012, steve, Update, General, reflectivity of green welding glass gg#14ref.pdfgg14refl1Wps.png
    Reply  Fri Mar 30 17:37:09 2012, steve, Update, General, cutting green welding glass for beam dumps IMG_0096.JPG
    Reply  Thu May 17 15:31:22 2012, steve, Update, General, beam trap posts & clamps for vacuum 05161201.PDF05151201.PDF
Message ID: 6280     Entry time: Tue Feb 14 17:09:05 2012     In reply to: 6250
Author: steve 
Type: Update 
Category: General 
Subject: reflectivity of green welding glass 

 Schott, Athermal green welding glass, shade #14 reflectivity was measured in 1.2W,  ~1 mm diameter  beam of MC reflected.

The P polarization measurement  was done with the help of half wave plate and PBC

 

 

Attachment 1: gg#14ref.pdf  244 kB  | Show | Hide all | Show all
Attachment 2: gg14refl1Wps.png  63.212 MB  Uploaded Wed Feb 15 08:07:52 2012  | Hide | Hide all | Show all
gg14refl1Wps.png
ELOG V3.1.3-