40m QIL Cryo_Lab CTN SUS_Lab TCS_Lab OMC_Lab CRIME_Lab FEA ENG_Labs OptContFac Mariner WBEEShop
  40m Log  Not logged in ELOG logo
Entry  Tue Dec 13 16:31:40 2011, Zach, Update, IOO, PSL beam realigned into MC 
    Reply  Tue Dec 13 18:56:23 2011, rana, Update, IOO, PSL beam realigned into MC 
Message ID: 6114     Entry time: Tue Dec 13 18:56:23 2011     In reply to: 6113
Author: rana 
Type: Update 
Category: IOO 
Subject: PSL beam realigned into MC 

 

 Of course, looking at the MC transmission os the important thing, but I wonder if maybe we should also monitor the beam before it goes into the MC just to see if its the fault of the MC-WFS or not. In the bad old MZ days, I remember that the MC mirror alignment would drastically change the post-MC RAM.

It requires another PD/demod set, but may be illuminating in the end. 

Also, can someone please add some channels to EPICS which calibrate the RAM channels into RAM units?

ELOG V3.1.3-