Entry  Wed Dec 7 18:47:36 2011, Jenne, Update, RF System, RAM Mon is now being demodulated 
    Reply  Thu Dec 8 00:04:50 2011, rana, Update, IOO, RAM Mon is now being demodulated 
       Reply  Thu Dec 8 14:47:28 2011, Jenne, Update, IOO, EOM aligned to minimize RAM 
    Reply  Thu Dec 8 00:45:13 2011, Koji, Update, RF System, 4ch demod is ready 
       Reply  Thu Dec 8 22:44:55 2011, Koji, Update, RF System, 4ch demod test result RF_DEMOD_TEST_111208.pdf
Message ID: 6084     Entry time: Thu Dec 8 00:04:50 2011     In reply to: 6082     Reply to this: 6089
Author: rana 
Type: Update 
Category: IOO 
Subject: RAM Mon is now being demodulated 

Monitoring good, but remember that the EOM alignment must be done carefully to minimize the RAM before we can use these trends.