Message ID: 5990     Entry time: Wed Nov 23 16:55:57 2011
Author: Suresh 
Type: Update 
Category: IOO 
Subject: MC realigned 

The PSL alignment into the MC was too poor for the autolocker to engage.  So retaining the last coil slider settings on the MC_Align screen that Kiwamu wanted, I have realigned the PSL beam and recentered the beam on the WFS.

When the WFS_MASTER was burtrestored after the recent power shutdown, the values loaded into the output matrix were not optimal.  When we switch on the WFS loops now, the MC_TRANS loops seem to push the WFS into away from the best possible coupling to PSL.  So I have switched them off for now.   Will load a new optimised output matrix and measure the transfer functions to see what is going on.

 

 