Message ID: 5964     Entry time: Sun Nov 20 15:11:09 2011     Reply to this: 5966   5967   5968
Author: kiwamu 
Type: Update 
Category: IOO 
Subject: RFAM monitoring test 

DO NOT CHANGE THE IFO ALIGNMENT UNTIL TOMORROW MORNING OR FURTHER NOTICE.

Plus, MC has to be kept locked with the WFS.

 

An RFAM measurement is ongoing

 

 Since the Stochmon turned out to be tricky to calibrate the outputs, Koji and I decided to monitor the RFAMs using REFL11 and REFL55 RFPDs while the beam is single-bounced from PRM.
This is, of course, not a permanent RFAM monitor, but at least it gives us a long-term continuous RFAM information for the first time.
Before the measurement I ran the offset zeroing scripts, therefore any offsets from electronics must be tiny in the acquired REFL signals.
The measurement has begun from approximately 3:00 pm.
 
 Also I found C1LSC.ini file again became default (no channels had been acquired).
So I replaced it with an archived ini file and then restarted fb.