40m QIL Cryo_Lab CTN SUS_Lab TCS_Lab OMC_Lab CRIME_Lab FEA ENG_Labs OptContFac Mariner WBEEShop
  40m Log  Not logged in ELOG logo
Entry  Tue Oct 18 21:19:18 2011, rana, Configuration, IOO, WFS disabled in SUS 
    Reply  Tue Oct 18 22:47:09 2011, Suresh, Configuration, IOO, MC autolocker script edited to shutdown and restart WFS loops  
Message ID: 5689     Entry time: Tue Oct 18 22:47:09 2011     In reply to: 5688
Author: Suresh 
Type: Configuration 
Category: IOO 
Subject: MC autolocker script edited to shutdown and restart WFS loops  

Quote:

I found that the MC WFS had large offset control signals going to the MC SUS. Even though the input switch was off, the integrators were holding the offset.

I have disabled the ASCPIT outputs in the MC SUS. Suresh is going to fix the MC autolocker script to gracefully handle the OFF and ON and then test the script before resuming the WFS testing.

MCL data for OAF may be suspect from this morning.

 I have edited (uncommented existing commands)  the following scripts to enable WFS locking to come on when the MC is locked.

1) $scripts$/MC/autolockMCmain40m*

2) $scripts$/MC/mcup

3) $scripts$/MC/mcdown

4) $scripts$/MC/WFS/mcwfson

5) $scripts$/MC/WFS/mcwfsoff.

I have checked that the autolocker script switches off the mcwfs when mc loses lock and then switches it on after re-obtaining lock.

 

ELOG V3.1.3-