40m QIL Cryo_Lab CTN SUS_Lab TCS_Lab OMC_Lab CRIME_Lab FEA ENG_Labs OptContFac Mariner WBEEShop
  40m Log  Not logged in ELOG logo
Entry  Mon Oct 3 14:05:41 2011, Jenne, Update, SUS, Failing to set SUS summary screen values 
    Reply  Mon Oct 3 17:27:23 2011, Jenne, Update, SUS, Failing to set SUS summary screen values 
       Reply  Sun Oct 16 05:35:18 2011, rana, Update, Computer Scripts / Programs, Failing to set SUS summary screen values 
          Reply  Thu Oct 20 09:54:53 2011, jamie, Update, Computer Scripts / Programs, pynds working on pianosa again 
Message ID: 5601     Entry time: Mon Oct 3 14:05:41 2011     Reply to this: 5604
Author: Jenne 
Type: Update 
Category: SUS 
Subject: Failing to set SUS summary screen values 

I assume it's because the burt restore didn't work for the SUS summary screen, but all of the values for the ifo suspensions (not the MCs...they're okay) are red. 

I am trying to run Rana's setSensors.py script, but am failing.  Any inspiration would be appreciated:

rosalba:SUS_SUMMARY>./setSensors.py 1001708529 500 .1 .25
['./setSensors.py', '1001708529', '500', '.1', '.25']
/cvs/cds/caltech/apps/linux64/python/lib64/python2.4/site-packages/nds/__init__.py:28: RuntimeWarning: No protocol specified, attempting protocol nds_v2
  super(daq, self).__init__(host, port)
Connecting NDS2 .... authenticate done
Traceback (most recent call last):
  File "./setSensors.py", line 81, in ?
    mean = acquire(x)
  File "./setSensors.py", line 73, in acquire
    daq.request_channel(chans[x])
Boost.Python.ArgumentError: Python argument types in
    daq.request_channel(daq, str)
did not match C++ signature:
    request_channel(_daq_t {lvalue}, daq_channel_t*)

I'm not exactly sure what the problem is.  Line 73, looks like it should have 2 arguments in the daq.request_channel, but even if I put in the "daq" variable (which is set a few lines above), I get the exact same error.  So...something else is wrong.  Ideas from someone who "speaks" python??