40m QIL Cryo_Lab CTN SUS_Lab TCS_Lab OMC_Lab CRIME_Lab FEA ENG_Labs OptContFac Mariner WBEEShop
  40m Log  Not logged in ELOG logo
Entry  Wed Sep 14 01:21:17 2011, Jenne, Update, Adaptive Filtering, Modifications to LSC, RFM models, added OAF model 
    Reply  Wed Sep 14 12:01:05 2011, rana, Update, Adaptive Filtering, Modifications to LSC, RFM models, added OAF model 
       Reply  Mon Sep 26 18:59:11 2011, Jenne, Update, Adaptive Filtering, Plan for making MC_F 
          Reply  Tue Sep 27 09:47:52 2011, Suresh, Update, Adaptive Filtering, Plan for making MC_F 
             Reply  Tue Sep 27 11:52:33 2011, Jenne, Update, Adaptive Filtering, Plan for making MC_F 
    Reply  Sun Sep 18 15:34:09 2011, Koji, Update, Adaptive Filtering, Modifications to LSC, RFM models, added OAF model 
    Reply  Tue Dec 13 01:20:38 2011, Den, Update, Adaptive Filtering, Modifications to LSC, RFM models, added OAF model 
Message ID: 5550     Entry time: Mon Sep 26 18:59:11 2011     In reply to: 5404     Reply to this: 5555
Author: Jenne 
Type: Update 
Category: Adaptive Filtering 
Subject: Plan for making MC_F 

Quote:

For the acquisition of the MC_F channel, I suggest taking the FAST_MON BNC output from the blue FSS interface card in the Eurocard crate in the PSL rack. This can then be piped into the 2-pin LEMO plug (Ch. 1) of the Generic Pentek DAQ card which used to acquire the MC_L signal from the MC Servo Board.

 [Jenne, Den]

Suresh tells us that he already has this channel physically plugged in.  Probably as a result of Valera's MCASS work.  Neat.  We just have to make the channel.  Right now the signal goes straight into some lockin stuff, so there is no actual "C1:IOO-MC_F" channel.

We don't want to make the new channel right now, since it is nighttime, and Kiwamu and Suresh are working on things.  So.  Tomorrow.  In the morning:

We will add a fast test point to the C1IOO model, and call it "C1:IOO-MC_F".  We will also route this signal via memory stuff over to the OAF model so that we can do adaptive filtering on the MC.  Then we will compile all the things.  Or at least all the things that we touched.  This will go hand-in-hand with the compling of Mirko's sweet new OAF model, which we were planning on compiling in the morning anyway.  Neat.

Things to compile tomorrow:  c1ioo and c1rfm, because of channel routing.  c1oaf because of all the new stuff.  That should be all.

ELOG V3.1.3-