Entry  Thu Sep 15 22:31:44 2011, Manuel, Update, SUS, Summary screen sussum.png
    Reply  Mon Sep 19 18:05:27 2011, rana, Update, SUS, Summary screen sussum.png
       Reply  Wed Sep 21 16:22:14 2011, rana, Update, SUS, Summary screen 
Message ID: 5467     Entry time: Mon Sep 19 18:05:27 2011     In reply to: 5428     Reply to this: 5500
Author: rana 
Type: Update 
Category: SUS 
Subject: Summary screen 

Quote:

I changed some colors on the Summary of Suspension Sensor  using my italian creativity.

I wrote a script in Python to change the thresholds for the "alarm mode" of the screen.

I've started to fix up the script somewhat (as a way to teach myself some more python):

* moved all of the SUS Summary screen scripts into SUS/SUS_SUMMARY/

* removed the hardcoded channel names (a list of 190 hand-typed names !!!!!!!)

* fixed it to use NDS2 instead of try to use the NDS2 protocol on fb:8088 (which is an NDS1 only machine)

* it was trying to set alarms for the SUS gains, WDs, Vmons, etc. using the same logic as the OSEM PD values. This is non-sensical. We'll need to make a different logic for each type of channel.

New script is called setSensors.py. There are also different scripts for each of the different kinds of fields (gains, sensors, vmons, etc.)

Some Examples:

pianosa:SUS_SUMMARY 0> ./setDogs.py 3 5
Done writing new values.

sussum.png