Entry  Sat Sep 10 14:55:28 2011, Keiko, Update, LSC, 3f demodulation board check 
    Reply  Sat Sep 10 16:10:42 2011, Keiko, Update, LSC, 3f demodulation board check REFL33-input-filter.png
       Reply  Sat Sep 10 18:57:52 2011, Keiko, Update, LSC, 3f demodulation board check 
          Reply  Sun Sep 11 15:19:39 2011, kiwamu, Update, LSC, phase delay in RF signals 
       Reply  Sun Sep 11 22:36:32 2011, Keiko, Update, LSC, 3f demodulation board check REFL33.pngREFL165.png
          Reply  Mon Sep 12 13:24:07 2011, Keiko, Update, LSC, 3f demodulation board check 
             Reply  Mon Sep 12 16:27:01 2011, Keiko, Update, LSC, 3f demodulation board check 
                Reply  Mon Sep 12 18:40:35 2011, Keiko, Update, LSC, 3f demodulation board check 
                   Reply  Tue Sep 13 15:00:25 2011, Keiko, Update, LSC, 3f demodulation board check WF33.pdfWF165.pdf
                      Reply  Tue Sep 13 23:08:51 2011, Keiko, Update, LSC, 3f demodulation board check REFL33-modified.pngREFL165-modified.png
                         Reply  Thu Sep 15 01:06:20 2011, Keiko, Update, LSC, 3f demodulation board check 
                            Reply  Fri Sep 16 21:26:12 2011, Keiko, Update, LSC, 3f demodulation board check 
Message ID: 5440     Entry time: Fri Sep 16 21:26:12 2011     In reply to: 5412
Author: Keiko 
Type: Update 
Category: LSC 
Subject: 3f demodulation board check 

The demodulation phases and gains for the all existing channels, AS11, REFL11,REFL55, REFL165, and REFL33, were adjusted by the command "ezcawrite" commands. 

Scripts are: 

REFL165 ezcawrite C1:LSC-REFL165_Q_GAIN 0.934340 && ezcawrite C1:LSC-REFL165_PHASE_D -81.802479

REFL33

ezcawrite C1:LSC-REFL33_Q_GAIN 0.984244 && ezcawrite C1:LSC-REFL33_PHASE_D -89.618

REFL11

ezcawrite C1:LSC-REFL11_Q_GAIN 1.173418 && ezcawrite C1:LSC-REFL11_PHASE_D -442.882697

AS11
ezcawrite C1:LSC-AS11_Q_GAIN 0.975576 && ezcawrite C1:LSC-AS11_PHASE_D -93.12492

AS55

ezcawrite C1:LSC-AS55_Q_GAIN 0.999164 && ezcawrite C1:LSC-AS55_PHASE_D -89.300986