Entry  Thu Sep 15 18:24:54 2011, Paul, Update, SUS, ITMY and SRM Oplev current status - comparison with ITMY oplev_spectra_comparison.pdf
    Reply  Thu Sep 15 18:31:27 2011, Paul, Update, SUS, ITMY and SRM Oplev current status - comparison with ITMY 
Message ID: 5422     Entry time: Thu Sep 15 18:24:54 2011     Reply to this: 5423
Author: Paul 
Type: Update 
Category: SUS 
Subject: ITMY and SRM Oplev current status - comparison with ITMY 

Just to find out where we are currently, I plotted the ITMY and SRM oplev spectra along with the ETMY oplev spectra. ETMY seems to be very good, so comparing with this seemed useful, so we know how much we have to improve by. The SRM power spectrum appears to be around 2 orders of magnitude higher than ETMY over pretty much the whole measurement band. The ITMY power spectrum is not so bad as the SRM above about 60Hz. Next thing to do is to check the dark noise level for the ITMY and SRM QPDs.

Attachment 1: oplev_spectra_comparison.pdf  23 kB  | Hide | Hide all
oplev_spectra_comparison.pdf