Entry  Thu Sep 15 15:11:38 2011, kiwamu, Update, SUS, f2a filters on BS and PRM PRMf2a.pngBS_f2a.png
    Reply  Fri Sep 16 16:29:05 2011, kiwamu, Update, SUS, f2a filters on SRM F2ASRM_Sep16.png
Message ID: 5417     Entry time: Thu Sep 15 15:11:38 2011     Reply to this: 5435
Author: kiwamu 
Type: Update 
Category: SUS 
Subject: f2a filters on BS and PRM 

The f2a filters were newly designed and installed on BS and PRM.

So the lock of PRMI will be more stable .

Once the SRM oplev project settles down, I will adjust the f2a filters on SRM too.