Message ID: 5404     Entry time: Wed Sep 14 12:01:05 2011     In reply to: 5402     Reply to this: 5550
Author: rana 
Type: Update 
Category: Adaptive Filtering 
Subject: Modifications to LSC, RFM models, added OAF model 

For the acquisition of the MC_F channel, I suggest taking the FAST_MON BNC output from the blue FSS interface card in the Eurocard crate in the PSL rack. This can then be piped into the 2-pin LEMO plug (Ch. 1) of the Generic Pentek DAQ card which used to acquire the MC_L signal from the MC Servo Board.