Category: SUS 
Subject: SUS spectra before close up 

Here are all suspension diagonalization spectra before close up. Notes:

  • TMX looks the worst, but I think we can live with it. The large glitch in the UL sensor at around 999423150 (#5355) is worrying. However, it seemed to recover. The spectra below were taken from data before the glitch.
  • ITMY has a lot of imaginary components. We previously found that this was due to a problem with one of it's whitening filters (#5288). I assume we're seeing the same issue here.
  • SRM needs a little more data to be able to distinguish the POS and SIDE peaks, but otherwise it looks ok.
ITMX ITMX.png        pit     yaw     pos     side    butt
UL    0.355   0.539   0.976  -0.500   0.182 
UR    0.833  -1.406  -0.307  -0.118   0.537 
LR   -1.167   0.055   0.717  -0.445   0.286 
LL   -1.645   2.000   2.000  -0.828  -2.995 
SD   -0.747   0.828   2.483   1.000  -1.637 
8.01148
ITMY  ITMY.png        pit     yaw     pos     side    butt
UL    1.003   0.577   1.142  -0.038   0.954  
UR    0.582  -1.423   0.931  -0.013  -1.031  
LR   -1.418  -0.545   0.858   0.008   1.081  
LL   -0.997   1.455   1.069  -0.017  -0.934  
SD   -0.638   0.797   1.246   1.000   0.264
 4.46659
BS  BS.png        pit     yaw     pos     side    butt
UL    1.612   0.656   0.406   0.277   1.031  
UR    0.176  -1.344   1.683  -0.058  -0.931  
LR   -1.824  -0.187   1.594  -0.086   0.951  
LL   -0.388   1.813   0.317   0.249  -1.087  
SD    0.740   0.301  -3.354   1.000   0.035 
 5.49597
PRM  PRM.png        pit     yaw     pos     side    butt
UL    0.546   1.436   1.862  -0.345   0.866  
UR    1.350  -0.564   0.551  -0.055  -0.878  
LR   -0.650  -0.977   0.138   0.023   0.858  
LL   -1.454   1.023   1.449  -0.268  -1.398  
SD    0.634  -0.620  -0.729   1.000   0.611
 5.78216
SRM      
ETMX ETMX.png        pit     yaw     pos     side    butt
UL    0.863   1.559   1.572   0.004   1.029  
UR    0.127  -0.441   1.869   0.480  -1.162  
LR   -1.873  -0.440   0.428   0.493   0.939  
LL   -1.137   1.560   0.131   0.017  -0.871  
SD    1.838   3.447  -0.864   1.000  -0.135 
 5.5259
ETMY  ETMY.png        pit     yaw     pos     side    butt
UL   -0.337   1.275   1.464  -0.024   0.929  
UR    1.014  -0.725   1.414  -0.055  -1.102  
LR   -0.649  -1.363   0.536  -0.039   0.750  
LL   -2.000   0.637   0.586  -0.007  -1.220  
SD    0.057  -0.016   1.202   1.000   0.142 
 4.22572
MC1  MC1.png        pit     yaw     pos     side    butt
UL    0.858   0.974   0.128   0.053  -0.000  
UR    0.184  -0.763   0.911   0.018   0.001  
LR   -1.816  -2.000   1.872   0.002   3.999  
LL   -1.142  -0.263   1.089   0.037   0.001  
SD    0.040   0.036  -0.216   1.000  -0.002 
 5.36332
MC2  MC2.png        pit     yaw     pos     side    butt
UL    1.047   0.764   1.028   0.124   0.948  
UR    0.644  -1.236   1.092  -0.088  -0.949  
LR   -1.356  -0.680   0.972  -0.096   1.007  
LL   -0.953   1.320   0.908   0.117  -1.095  
SD   -0.092  -0.145  -0.787   1.000  -0.065 
 4.029
MC3  MC3.png        pit     yaw     pos     side    butt
UL    1.599   0.343   1.148   0.168   1.101  
UR    0.031  -1.647   1.139   0.202  -1.010  
LR   -1.969   0.010   0.852   0.111   0.893  
LL   -0.401   2.000   0.861   0.077  -0.995  
SD   -0.414   0.392  -1.677   1.000   0.018 
3.61734

 

ELOG V3.1.3-