Entry  Thu Jun 30 03:26:40 2011, kiwamu, Update, ABSL, status update 
    Reply  Thu Jun 30 14:11:55 2011, kiwamu, Update, ABSL, a photo of ABSL setup on the AP table ABSLsetup.png
       Reply  Tue Jul 5 16:09:54 2011, kiwamu, Update, ABSL, some photos for ABSL setup APtable.pngPSLtable.png
    Reply  Thu Jun 30 21:00:20 2011, kiwamu, Update, ABSL, fine alignment done 
Message ID: 4923     Entry time: Thu Jun 30 14:11:55 2011     In reply to: 4917     Reply to this: 4939
Author: kiwamu 
Type: Update 
Category: ABSL 
Subject: a photo of ABSL setup on the AP table 

Here is a picture of the latest ABSL setup at the east part of the AP table.

ABSLsetup.png

 

(Some notes )

 - The ABSL laser is injected from the AP port.

  - A 90 % reflection BS was installed just after the NPRO, this is for sampling a 10% of the laser to the PSL table.

    However, I've just realized that this is not a nice way because the 10 % beam doesn't  go through the Faraday. Whoops.

 - A polarzser cell at the input side of the Faraday doesn't let any beam go through it for some reasons (broken ?).

    Therefore instead of having such a bad cell, a cube PBS was installed.

 -  A room was left on the table for the AS165 RFPD (green-dashed rectangular in the picture).

Quote from #4917

 - Also a picture of the setup will be uploaded in the morning.

 