Entry  Wed Jun 1 11:31:50 2011, josephb, Update, CDS, MC1 LR digital reading close to zero, readback ~0.7 volts 
    Reply  Sun Jun 26 22:38:20 2011, rana, Update, CDS, MC1 LR dead for > 1 month; now revived temporarily lrsen.pngbt.jpg
       Reply  Mon Jun 27 00:23:11 2011, rana, Update, CDS, ETMX SIDE problem etmx-side.png
       Reply  Fri Nov 18 01:12:14 2011, Suresh, Update, CDS, MC1 LR dead for > 1 month; now revived temporarily 
Message ID: 4889     Entry time: Mon Jun 27 00:23:11 2011     In reply to: 4888
Author: rana 
Type: Update 
Category: CDS 
Subject: ETMX SIDE problem 

The slow readback of the ETMX side seems to also have something flaky and bi-stable. This is not an issue for damping, but it disables the SIDE watchdog for ETMX and makes it unsafe if we accidentally use the wrong damping sign.

Attachment 1: etmx-side.png  10 kB  | Hide | Hide all
etmx-side.png