Message ID: 4840     Entry time: Mon Jun 20 11:38:49 2011     In reply to: 4832     Reply to this: 4841   4842
Author: kiwamu 
Type: Update 
Category: ABSL 
Subject: I-P curve of LightWave M126-1064-700 

The I-P curve of the LightWave NPRO (M126-1064-700), which was taken out from the MOPA box, was measured. It looks healthy.

The output power can go up to about 1 W, but I guess we don't want it to run at a high power to avoid any further degradation since the laser is old.

 

IP_curve.png

 X-axis is the current read from the display of the controller. Y-axis is the output power, directly measured by Coherent PM10.

The measurement was done by changing the current from the controller.

Quote from #4832

 [Things to be done]

   - measure the beam profiles and power

   - get a laser controller, which will be dedicated for this laser, from Peter King