Subject: Alberto's 11MHz was modified to POP55MHz 

- Resonant at 55MHz. The transimpedance is 258Ohm. That is about half of REFL55 (don't know why).

- 11MHz&110MHz notch

- The 200MHz oscillation of MAX4106 was damped by the same recipe as REFL11.

POP55_transimpedance.pdf

 

Attachment 1: POP55_schematic_110520_KA.pdf  201 kB  | Hide | Hide all
POP55_schematic_110520_KA.pdf POP55_schematic_110520_KA.pdf
Attachment 2: POP55_transimpedance.pdf  29 kB  | Hide | Hide all
POP55_transimpedance.pdf
ELOG V3.1.3-