Message ID: 4743     Entry time: Wed May 18 22:11:31 2011     In reply to: 4735     Reply to this: 4766
Author: rana 
Type: Configuration 
Category: LSC 
Subject: New digital lockin added to LSC model/screen 

Untitled.png

 This is OK....but, the input matrix should come from the same place as the regular input matrix: i.e. it should be just another row like CARM, DARM, etc. rather than have its own screen.

Also, I think a nice mod to all the matrices would be if the ORANGE triangle was only visible when there's a signal flowing through it.