40m QIL Cryo_Lab CTN SUS_Lab TCS_Lab OMC_Lab CRIME_Lab FEA ENG_Labs OptContFac Mariner WBEEShop
  40m Log  Not logged in ELOG logo
Entry  Mon May 9 12:33:40 2011, kiwamu, Update, LSC, C1:LSC-TRIG_MTRX : wrong matrix size 
    Reply  Mon May 9 13:14:48 2011, josephb, Update, LSC, C1:LSC-TRIG_MTRX : wrong matrix size 
Message ID: 4665     Entry time: Mon May 9 13:14:48 2011     In reply to: 4664
Author: josephb 
Type: Update 
Category: LSC 
Subject: C1:LSC-TRIG_MTRX : wrong matrix size 

[Joe, Kiwamu]

There is a feature/bug of the RCG code that you can only have 1 receiving tag for every sending tag.  There were 5 tags which were being received by two tags each, for two different matrices.  Only the first tag was receiving, the second was apparently ignored.

This has been fixed temporarily by putting in direct lines in place of these 5 tags.

Quote:

I found that C1:LSC-TRIG_MTRX has a wrong matrix size. It needs to be fixed.

It is designed to have a 11x8 matrix in the simlink model file, but it's been compiled as a 6x8 matrix.

 

ELOG V3.1.3-