40m QIL Cryo_Lab CTN SUS_Lab TCS_Lab OMC_Lab CRIME_Lab FEA ENG_Labs OptContFac Mariner WBEEShop
  40m Log  Not logged in ELOG logo
Entry  Mon May 2 17:10:55 2011, steve, Update, SUS, PRM oplev 
    Reply  Tue May 3 16:20:13 2011, steve, Update, SUS, PRM & BS oplevs are ready P1070630.JPGP1070632.JPG
Message ID: 4616     Entry time: Tue May 3 16:20:13 2011     In reply to: 4599
Author: steve 
Type: Update 
Category: SUS 
Subject: PRM & BS oplevs are ready 

Quote:

The returning spot diameter on the qpd ~10 mm. In order to reduce the spot size I moved the f 1145 mm lens toward the PRM ~ 25 cm. The spot size was reduced to ~8 mm, 3200 counts.

I'll try to find an other lens tomorrow.

 Atm 1,  PRM oplev inward path with 2 lens solution: 14 cm gap between F 1145 and F 1545 mm lenses. 

Atm 2,   The PRM beam size 3 mm and the beam  quality is still bad. The BS path only needed alignment.

Attachment 1: P1070630.JPG  2.921 MB  | Show | Hide all | Show all
Attachment 2: P1070632.JPG  2.651 MB  | Hide | Hide all | Show all
P1070632.JPG
ELOG V3.1.3-