40m QIL Cryo_Lab CTN SUS_Lab TCS_Lab OMC_Lab CRIME_Lab FEA ENG_Labs OptContFac Mariner WBEEShop
  40m Log  Not logged in ELOG logo
Message ID: 4441     Entry time: Thu Mar 24 19:48:13 2011
Author: Aidan, Kiwamu 
Type: Update 
Category: Green Locking 
Subject: Designs for permanent electronics for ALS 

Kiwamu and I looked at all the electronics that are currently in place for the green locking on the X-arm and have made a set of block diagrams of the rack mounted units that we should build to replace the existing ... "works of art" that sprawl around out there at the moment.

Main items

1. "ETM Green Oscillator/PDH support box". Not a great name but this would provide the local oscillator signal for the end PDH (with a controllable phase rotator) as well as the drive oscillator for the end laser PZT. Since we need to hit a frequency of 216.075kHz with a precision that Kiwamu needs to determine, we'd need to be able to tune the oscillator ... it needs to be a VCO. It'd be nice to be able to measure the output frequency so I've suggested dividing it down by N times to put it into the DAQ - maybe N = 2^7 = 128x to give a measured frequency of around 1.7kHz. Additionally this unit will sum the PDH control signal into the oscillation. This box would support the Universal PDH box that is currently at the X-end.

2. "Vertex X-arm beatnote box" - this basically takes the RF and DC signals from the beatnote PD and amplifies them. It provides a monitor for the RF signal and then converts the RF signal into a square wave in the comparator.

3. "Mixer Frequency Discriminator" - just the standard MFD setup stored in a box. For temperature stability reasons, we want to be careful about where we store this box and what it is made of. That's also the reason that this stage is separated from the X-arm beatnote box with it's high-power amps.

Other things

4. RS232 and EPICS control of the doubling ovens

5. Intensity stabilization of the End Laser

P.S. I used Google Diagrams for the pictures.

Attachment 1: GreenLockingElectronics.pdf  36 kB  | Show | Hide all | Show all
Attachment 2: GreenEndPDHsupportboxandLO.pdf  20 kB  Uploaded Thu Mar 24 20:55:54 2011  | Show | Hide all | Show all
Attachment 3: VertexBeatnoteAmplifierandComparator.pdf  27 kB  Uploaded Thu Mar 24 20:56:13 2011  | Show | Hide all | Show all
Attachment 4: MixerFrequencyDiscriminator.pdf  18 kB  Uploaded Thu Mar 24 20:56:26 2011  | Hide | Hide all | Show all
MixerFrequencyDiscriminator.pdf
ELOG V3.1.3-