Message ID: 4184     Entry time: Fri Jan 21 17:59:27 2011
Author: josephb, alex 
Type: Update 
Category: CDS 
Subject: Fixed Dolphin transmission 

The orientation of the Dolphin cards seems to be opposite on c1lsc and c1sus.  The wide part is on top on c1lsc and on the bottom on c1sus.  This means, the cable is plugged into the left Dolphin port on c1lsc and into the right Dolphin port on c1sus.  Otherwise you get a wierd state where you receive but not transmit.