40m QIL Cryo_Lab CTN SUS_Lab TCS_Lab OMC_Lab CRIME_Lab FEA ENG_Labs OptContFac Mariner WBEEShop
  40m Log  Not logged in ELOG logo
Entry  Wed Jan 19 04:25:54 2011, Kevin, Update, Electronics, POX Transfer Functions 
    Reply  Wed Jan 19 10:45:00 2011, Koji, Update, Electronics, POX Transfer Functions 
       Reply  Wed Jan 19 17:00:23 2011, Kevin, Update, Electronics, POX Transfer Functions 
          Reply  Thu Jan 20 01:50:30 2011, Kevin, Update, Electronics, POX Transfer Functions 
Message ID: 4172     Entry time: Thu Jan 20 01:50:30 2011     In reply to: 4170
Author: Kevin 
Type: Update 
Category: Electronics 
Subject: POX Transfer Functions 

[Koji, Kevin]

We fit the entire POX optical transfer function from 1 MHz to 500 MHz in LISO. The fit is on the wiki at http://lhocds.ligo-wa.caltech.edu:8000/40m/Electronics/POX. Using LISO's root fitting mode, we found that the transfer function has five poles and four zeros.

I will work on making plots of the residuals. This is difficult because by default, LISO does not calculate the fitting function at the frequencies of the data points themselves and I haven't figured out how to force it to do this yet.