Message ID: 4009     Entry time: Fri Dec 3 15:37:10 2010
Author: josephb 
Type: Update 
Category: CDS 
Subject: fb, front ends fixed - tested RFM between c1ioo and c1iscex 

Problem:

The front ends and fb computers were unresponsive this morning.

This was due to the fb machine having its ethernet cable plugged into the wrong input.   It should be plugged into the port labeled 0.

Since all the front end machines mount their root partition from fb, this caused them to also hang.

Solution:

The cable has been relabled to "fb" on both ends, and plugged into the correct jack.  All the front ends were rebooted.

 

Testing RFM for green locking:

I tested the RFM connection between c1ioo and c1scx.  Unfortunately, on the first test, it turns out the c1ioo machine had its gps time off by 1 second compared to c1sus and c1iscex.  A second reboot seems to have fixed the issue.

However, it bothers me that the code didn't come up with the correct time on the first boot.

The test was done using the c1gcv model and by modifying the c1scx model.  At the moment, the MC_L channel is being passed the MC_L input of the ETMX suspension.  In the final configuration, this will be a properly shaped error signal from the green locking.

The MC_L signal is currently not actually driving the optic, as the ETMX POS MATRIX currently has a 0 for the MC_L component.