Message ID: 4004     Entry time: Wed Dec 1 13:41:21 2010
Author: josephb, alex, rolf 
Type: Update 
Category: CDS 
Subject: Timing is back 

Problem:

We had timing problems across the front ends.

Solution:

Noticing that the 1PPS reference was not blinking on the Master Timing Distribution box.  It was supposed to be getting a signal from the c0dcu1 VME crate computer, but this was not happening.

We disconnected the timing signal going into c0dcu1, coming from c0daqctrl, and connected the 1PPS directly from c0daqctrl to the Ref In for the Master Timing distribution box (blue box with lots of fibers coming out of it in 1X5).

We now have agreement in timing between front ends.

After several reboots we now have working RFM again, along with computers who agree on the current GPS time along with the frame builder.

Status:

RFM is back and testpoints should be happy.

We still don't have a working binary output for the X end.  I may need to get a replacement backplane with more than 4 slots if the 1st slot of this board has the same problem as the large boards.

I have burt restored the c1ioo, c1mcs, c1rms, c1sus, and c1scx processes, and optics look to be damped.

 

ELOG V3.1.3-