Message ID: 3911     Entry time: Fri Nov 12 20:40:51 2010
Author: josephb, yuta, valera 
Type: Configuration 
Category: Electronics 
Subject: AA voltage range 

We changed the range of the two SUS AA boards in the corner from +/-2 V to +/-10 V by changing the supply voltage from +/-5 V to +/-15 V. The change was made by switching the AA power feed wires on  the cross connect. The max supply according to the spec of DRV134/INA134 is +/-18 V.

We checked the new range by applying the voltage to the input of AA and measuring the output going to the ADCs. The local damping MC1,2,3 appears to work.