40m QIL Cryo_Lab CTN SUS_Lab TCS_Lab OMC_Lab CRIME_Lab FEA ENG_Labs OptContFac Mariner WBEEShop
  40m Log  Not logged in ELOG logo
Entry  Tue Mar 11 23:14:01 2008, rana, Configuration, PEM, Accelerometer and Seismometer movements Acc.pdf
    Reply  Wed Mar 12 00:36:52 2008, rana, Configuration, PEM, Accelerometer and Seismometer movements finished.pdf
       Reply  Wed Mar 12 00:40:35 2008, rana, Configuration, PEM, Accelerometer and Seismometer movements mc2048-128.pdf
          Reply  Wed Mar 12 00:47:26 2008, rana, Configuration, PEM, Accelerometer and Seismometer movements Screenshot.png
          Reply  Mon Mar 17 18:30:48 2008, mevans, Configuration, PEM, Adaptive Filtering mcacc_adaptive.png
Message ID: 384     Entry time: Mon Mar 17 18:30:48 2008     In reply to: 370
Author: mevans 
Type: Configuration 
Category: PEM 
Subject: Adaptive Filtering 
It seems that adaptive filtering can achieve results similar to those of the MISO FIR Wiener (entry 369). The adaptive code simulates real-time operation, but uses the same data used by Rana for the Wiener filter. I ran the adaptive filter over the data 100 times to ensure that it was well trained... maybe too well.
Attachment 1: mcacc_adaptive.png  21 kB  | Show | Show all
ELOG V3.1.3-