Subject: [EMERGENCY] accidentally deleted daqd 

Problem:

Missing daqd file, i.e. the framebuilder executable.

Solution:

1) Go to /opt/rtcds/caltech/c1/core/advLigoRTS/

2) Look in the Makefile for a likely build suspect.  In this case it was build dc, which stands for data concentrator.

3) So we ran "make dc"

4) Go to the sub-directory build/dc/ and then copy the daqd file there to the /opt/rtcds/caltech/c1/target/fb directory

5) Test it to ensure we're getting channels (Yay!)

Future Safeguards:

Place the new target directory under SVN control.

 