We found today that there was some (unforgivably un-elogged) PSL-POS & PSL-ANG work today.

The wedge splitter at the end of the PSL table is so terribly dogged that it actually moves around irreversibly if you touch the post a little. Pictures have been recorded for the hall of shame. This should be replaced with a non-pedestal / fork mount.

I was so sad about the fork clamp, that I edited the SUS Master screen instead according to Joe-Yuta instructions; see attached.Untitled.png

There's clearly several broken/white links on there, but I guess that Yuta is going to find out how to fix these from Joe in the morning.