40m QIL Cryo_Lab CTN SUS_Lab TCS_Lab OMC_Lab CRIME_Lab FEA ENG_Labs OptContFac Mariner WBEEShop
  40m Log  Not logged in ELOG logo
Message ID: 3628     Entry time: Thu Sep 30 16:29:35 2010
Author: josephb, alex 
Type: Update 
Category: CDS 
Subject: fb update 

There currently seems to be a timing issue with  the frame builder.  We switched over to using a symmetricom card to get an IRIG-B signal into the fb machine, but the gps time stamp is way off (~80 years Alex said).

If there is a frame buiilder issue, its currently often necessary to kill the associated mx_stream processes, since they don't seem to restart gracefully.  To fix it the following steps should be taken:

Kill frame builder, kill the two mx_stream processes, then /etc/restart_streams/, then restart the frame builder (usual daqd -c ./daqdrc >& ./daqd.log in /opt/rtcds/caltech/c1/target/fb).

To restart (or start after a boot) the nds server, you need to go to /opt/rtcds/caltech/c1/target/fb and type

./nds /opt/rtcds/caltech/c1/target/fb/pipe

At this time, testpoints are kind of working, but timing issues seem to be preventing useful work being done with it.  I'm leaving with Alex working on the code.

 

ELOG V3.1.3-