40m QIL Cryo_Lab CTN SUS_Lab TCS_Lab OMC_Lab CRIME_Lab FEA ENG_Labs OptContFac Mariner WBEEShop
  40m Log  Not logged in ELOG logo
Entry  Wed Aug 18 19:14:59 2010, Jenne, Update, elog, elog dead again 
    Reply  Thu Aug 19 01:49:14 2010, Jenne, Update, elog, elog dead again 
       Reply  Thu Aug 19 09:51:43 2010, josephb, Update, elog, elog dead again 
Message ID: 3440     Entry time: Thu Aug 19 09:51:43 2010     In reply to: 3439
Author: josephb 
Type: Update 
Category: elog 
Subject: elog dead again 

I found the elog dead again this morning, and the script didn't kill again. I modified the script to use the following line instead of "pkill elogd":

kill `ps -ef | grep elogd | grep -v grep | grep -v start-elog-nodus | awk '{print $2}'`

Hopefully the script will be a bit more robust in the future.

Quote:

Quote:

The elog was so dead this time that the restart script didn't work.  I followed the restart-by-hand instructions instead, with success.

 Just for added interest, I tried a different method when the restart script broke.  The "start-elog-nodus" script has a line "kill elogd".  This seems not to be actually killing anything anymore, which means the elog can't restart.  So this time I went for "kill <pid number>", and then ran the startup script.  This worked.  So it's the "kill elogd" which isn't working reliably.

 