40m
QIL
Cryo_Lab
CTN
SUS_Lab
TCS_Lab
OMC_Lab
CRIME_Lab
FEA
ENG_Labs
OptContFac
Mariner
WBEEShop
|
40m Log |
Not logged in |
 |
|
Mon Feb 18 12:04:39 2008, Alberto, Update, Electronics, RF Monitor (StocMon)
|
Fri Feb 22 08:29:07 2008, Alberto, Update, Electronics, RF Monitor (StocMon)
|
Fri Feb 22 11:13:15 2008, rob, Update, Electronics, RF Monitor (StocMon)
|
Fri Feb 22 08:33:18 2008, Alberto, Update, Electronics, RF Monitor (StocMon)
|
Thu Feb 28 19:49:21 2008, rob, Update, Electronics, RF Monitor (StocMon)
|
|
Message ID: 332
Entry time: Fri Feb 22 08:33:18 2008
In reply to: 321
Reply to this: 347
|
Author: |
Alberto |
Type: |
Update |
Category: |
Electronics |
Subject: |
RF Monitor (StocMon) |
|
|
Quote: | I put the amplifiers next to the monitor on the PSL table, layed the power and the RF SMA cables out to the rack. I'm powering the box and the amplifiers with the power supply, waiting for someone to show me tomorrow how to connect it to the Sorensen (Steve, Ben?).
I'm ready to hook up the channels into EPICS. |
With Ben, we hooked up the RF Monitor box into the PSL rack and created 4 EPICS channels for the outputs:
C1:IOO_RF_STOC_MON_33
C1:IOO_RF_STOC_MON_133
C1:IOO_RF_STOC_MON_166
C1:IOO_RF_STOC_MON_199
The power cable bringing +15V to the preamplifier on the PSL table should be replaced eventually. |