Sat Jun 12 19:41:04 2010, Alberto, Update, Locking, 40m Upgrade Optickle Model
|
Sun Jun 13 08:28:44 2010, valera, Update, Locking, 40m Upgrade Optickle Model
|
Mon Jun 14 07:57:07 2010, alberto, Update, Locking, 40m Upgrade Optickle Model
|
Tue Jun 15 21:28:44 2010, alberto, Update, Locking, 40m Upgrade Optickle Model  
|
|
Message ID: 3075
Entry time: Mon Jun 14 07:57:07 2010
In reply to: 3074
Reply to this: 3079
|
Author: |
alberto |
Type: |
Update |
Category: |
Locking |
Subject: |
40m Upgrade Optickle Model |
|
|
Quote: |
In my calculation of the digital filters of the optical transfer functions the carrier light is resonant in coupled cavities and the sidebands are resonant in recycling cavities (provided that macroscopic lengths are chosen correctly which I assumed).
|
Carrier and SB (f2) shouldn't be resonant at the same time in the SRC-arms coupled cavity. No additional filtering of the GW signal is wanted.
The SRC macroscopic length is chosen to be = c / f2 - rather than = [ (n+1/2) c / (2*f2) ] - accordingly to that purpose. |