40m
QIL
Cryo_Lab
CTN
SUS_Lab
TCS_Lab
OMC_Lab
CRIME_Lab
FEA
ENG_Labs
OptContFac
Mariner
WBEEShop
|
40m Log |
Not logged in |
 |
|
Sun May 16 12:51:08 2010, kiwamu, Update, Green Locking, reflected beam at PD
|
Sun May 16 19:25:45 2010, Koji, Update, Green Locking, reflected beam at PD
|
Thu May 20 13:29:40 2010, kiwamu, Update, Green Locking, mode profile at PPKTP crystal
|
Thu May 20 14:18:59 2010, kiwamu, Update, Green Locking, mode profile of 40m cavity
|
Wed May 26 04:14:21 2010, kiwamu, Update, Green Locking, locked
|
Wed May 26 14:38:02 2010, Koji, Update, Green Locking, locked
|
Thu May 27 02:22:24 2010, kiwamu, Update, Green Locking, more details  
|
Thu May 27 09:43:50 2010, rana, Update, Green Locking, more details
|
Mon Jul 12 13:16:53 2010, kiwamu, Update, Green Locking, PZT feedback at X end
|
Wed Jun 9 11:13:11 2010, kiwamu, Update, Green Locking, lock with PDH box
|
Fri Jun 11 11:54:42 2010, kiwamu, Update, Green Locking, end PDH with thermal feedback 
|
Fri Jun 11 13:32:28 2010, Koji, Update, Green Locking, end PDH with thermal feedback
|
Sun Jun 20 18:28:25 2010, kiwamu, Update, Green Locking, Re: lock with PDH box
|
Wed Jul 21 19:11:18 2010, Dmass, Update, Green Locking, locked
|
|
Message ID: 2999
Entry time: Thu May 27 09:43:50 2010
In reply to: 2997
Reply to this: 3195
|
Author: |
rana |
Type: |
Update |
Category: |
Green Locking |
Subject: |
more details |
|
|
Quote: |
RMS which is integrated down to 1Hz is 1.6MHz.
This number is almost what I expected assuming the cavity swings with displacement of x ~< 1um.
|
Its OK, but the real number comes from measuring the time series of this in the daytime (not the spectrum). What we care about is the peak-peak value of the PZT feedback signal measured on a scope for ~30 seconds. You can save the scope trace as a PNG. |