40m
QIL
Cryo_Lab
CTN
SUS_Lab
TCS_Lab
OMC_Lab
CRIME_Lab
FEA
ENG_Labs
OptContFac
Mariner
WBEEShop
|
40m Log |
Not logged in |
 |
|
Mon May 10 16:59:35 2010, Alberto, Update, 40m Upgrading, Unexpected oscilaltionin the POY11 PD 
|
Mon May 10 18:56:53 2010, rana, Update, Electronics, Unexpected oscilaltionin the POY11 PD
|
Mon May 10 19:09:45 2010, rana, Update, Electronics, Unexpected oscilaltionin the POY11 PD
|
|
Message ID: 2905
Entry time: Mon May 10 19:09:45 2010
In reply to: 2904
|
Author: |
rana |
Type: |
Update |
Category: |
Electronics |
Subject: |
Unexpected oscilaltionin the POY11 PD |
|
|
Quote: |
Where did you get the 55nH based notch from? I don't remember anything like that from the other LSC PD schematics. This is certainly a bad idea. You should remove it and put the notch back over by the other notch.
|
Why is it a bad idea?
You mean putting both the 2-omega and the 55MHz notches next to each other right after the photodiode? |