Message ID: 2584     Entry time: Tue Feb 9 17:51:48 2010
Author: Jenne 
Type: Summary 
Category: IOO 
Subject: Input Mode Matching Telescope design is complete 

The upgrade's input mode matching telescope design is complete.  A summary document is on the MMT wiki page, as are the final distances between the optics in the chain from the mode cleaner to the ITMs.  Unless we all failed kindergarden and can't use rulers, we should be able to get very good mode matching overlap.  We seem to be able (in Matlab simulation land) to achieve better than 99.9% overlap even if we are wrong on the optics' placement by ~5mm.  Everything is checked in to the svn, and is ready for output mode matching when we get there.