Message ID: 2579     Entry time: Mon Feb 8 15:41:51 2010     In reply to: 2578
Author: Alberto 
Type: Update 
Category: ABSL 
Subject: Suddenly a much better alignment of PRC 

Quote:

Quote:

I just aligned PRM and locked PRC and I noticed that SPOB is much higehr than it used to be. It's now about 1800, vs 1200 than it used to be last week.

Isn't anyone related to that? If so, may I please know how he/she did it?

 oops, my bad.  I cranked the 33MHz modulation depth and forgot to put it back.  The slider should go back to around 3. 

 I was actually hoping that the alignment got better.