So that we can use both Guralps for Adaptive stuff, and so that I can look at the differential ground motion spectra, I've reconnected the Guralp Seismometers to the PEM ADCU, instead of where they've been sitting for a while connected to the ASS ADC. I redid the ASS.mdl file, so that the PEM and PEMIIR matricies know where to look for the Gur2 data. I followed the 'make ass' procedure in the wiki. The spectra of the Gur1 and Gur2 seismometers look pretty much the same, so everything should be all good.
There's a problem with DataViewer though: After selecting signals to plot, whenever I hit the "Start" button for the realtime plots, DataViewer closes abruptly.
When I open dataviewer in terminal, I get the following output:
allegra:~>dataviewer
Warning: communication protocol revision mismatch: expected 11.3, received 11.4
Warning: Not all children have same parent in XtManageChildren
Warning: Not all children have same parent in XtManageChildren
Warning: Not all children have same parent in XtManageChildren
Warning: Not all children have same parent in XtManageChildren
Warning: Not all children have same parent in XtManageChildren
Warning: communication protocol revision mismatch: expected 11.3, received 11.4
msgget: No space left on device
allegra:~>framer4 msgget:msqid: No space left on device
Does anyone have any inspiration for why this is, or what the story is? I have GR class, but I'll try to follow up later this afternoon. |