Message ID: 2437     Entry time: Mon Dec 21 02:22:31 2009     In reply to: 2434     Reply to this: 2441
Author: rana, jenne, kiwamu 
Type: Update 
Category: ASS 
Subject: OAF Model update and build instructions 

This allowed measuring the MC1 -> MCL TF finally. Its mostly flat. Data saved as Templates/OAF/OAF-MCLTF.xml

Attachment 1: Untitled.png  356 kB  | Hide | Hide all
Untitled.png