Thu Dec 10 13:10:25 2009, Alberto, Configuration, LSC, 166 LO Disconnected
|
Thu Dec 10 18:31:44 2009, Alberto, Configuration, LSC, 166 LO Disconnected
|
Fri Dec 11 09:30:09 2009, Koji, Configuration, LSC, 166 LO Disconnected
|
Fri Dec 11 11:42:26 2009, Alberto, Configuration, LSC, 166 LO Disconnected
|
Fri Dec 11 14:12:32 2009, rana, Configuration, LSC, 166 LO Disconnected
|
Fri Dec 11 19:51:13 2009, Alberto, Configuration, LSC, 166 LO Disconnected
|
Sat Dec 12 07:36:56 2009, rana, HowTo, Electronics, How to Measure the Length of a Cable: Interferometry
|
|
Message ID: 2396
Entry time: Fri Dec 11 11:42:26 2009
In reply to: 2395
Reply to this: 2398
|
Author: |
Alberto |
Type: |
Configuration |
Category: |
LSC |
Subject: |
166 LO Disconnected |
|
|
Quote: |
They must not be dBm, must be dB
Quote: |
Quote: |
I temporarily disconnected the Heliax cable that brings the 166MHz LO to the LSC rack.
I'm doing a couple of measurement and I'll put it back in as soon as I'm done.
|
These are the losses I measured on a RG-174 cable for the two frequencies that we're planning to use in the Upgrade:
@11MHz Loss=0.22dBm/meter
@55MHz Loss=0.41dBm/meter
(The cable was 2.07m long. The input signal was +10dBm and the output voltages at the oscilloscope where: Vpk-pk(11MHz)=1.90V, Vpk-pk(11MHz)=1.82V )
|
|
I apologize for the lack of correctness on the units in yesterday's elog entry, but I wasn't very sharp last night.
I repeated the measurement today, this time also making sure that I had a 50ohm input impedance set in the scope. These the results for the losses.
RG-174 Cable |
0.053 dB/m @ 11MHz |
0.155 dB/m @ 55 MHz |
I also measured the losses in the Heliax cable going from the 166 MHz LO to the LSC rack:
166MHz LO Heliax |
0.378 dB @ 11MHz |
1.084 dB @ 55 MHz |
|