40m
QIL
Cryo_Lab
CTN
SUS_Lab
TCS_Lab
OMC_Lab
CRIME_Lab
FEA
ENG_Labs
OptContFac
Mariner
WBEEShop
|
40m Log |
Not logged in |
 |
|
Thu Dec 10 13:10:25 2009, Alberto, Configuration, LSC, 166 LO Disconnected
|
Thu Dec 10 18:31:44 2009, Alberto, Configuration, LSC, 166 LO Disconnected
|
Fri Dec 11 09:30:09 2009, Koji, Configuration, LSC, 166 LO Disconnected
|
Fri Dec 11 11:42:26 2009, Alberto, Configuration, LSC, 166 LO Disconnected
|
Fri Dec 11 14:12:32 2009, rana, Configuration, LSC, 166 LO Disconnected
|
Fri Dec 11 19:51:13 2009, Alberto, Configuration, LSC, 166 LO Disconnected
|
Sat Dec 12 07:36:56 2009, rana, HowTo, Electronics, How to Measure the Length of a Cable: Interferometry
|
|
Message ID: 2384
Entry time: Thu Dec 10 13:10:25 2009
Reply to this: 2393
|
Author: |
Alberto |
Type: |
Configuration |
Category: |
LSC |
Subject: |
166 LO Disconnected |
|
|
I temporarily disconnected the Heliax cable that brings the 166MHz LO to the LSC rack.
I'm doing a couple of measurement and I'll put it back in as soon as I'm done. |